FlexPasser™ Tendon Retrieval Kit

For atraumatic retrieval of severed flexor tendons with minimal incisions
FlexPasser Hero Image Mobile

Watch

FlexPasser Tendon Retrieval Kit Surgical Technique Animation

For atraumatic retrieval of severed flexor tendons with minimal incisions.

The FlexPasser™ Tendon Retrieval Kit provides a system of single-use instrumentation for the retrieval of the retracted proximal tendon stump(s) during the repair of lacerated digital flexor tendon(s) in the hand.

 

USA and Canada
Visiting from the USA or Canada? Click the button below to view the Xiros North America Website.

Xiros North America

Indications

The FlexPasser Tendon Retrieval Kit provides a system of single use instrumentation for the retrieval of the retracted proximal tendon stump(s) during the repair of lacerated digital flexor tendon(s) in the hand.

Surgery to repair lacerated or severed flexor tendons in the hand can lead to additional trauma to the tendon end or tendon sheath which may cause adhesion post-operatively. This trauma and possible adhesion can reduce the range of movement and impair the outcome of the surgery (1,2,3).

1. Ahed, K., M. Moujtahid and M. Nechad (2014). “Retrieval of the retracted flexor tendons for long fingers: New tip.” Chirurgie de la Main 33(4): 247-250.

2. Dy, C. J., A. Hernandez-Soria, Y. Ma, T. R. Roberts and A. Daluiski (2012). “Complications After Flexor Tendon Repair: A Systematic Review and Meta-Analysis.” The Journal of Hand Surgery 37(3): 543-551.e541.

3. Ozturk, M. B., S. O. Basat, T. Kayadibi, M. Karahangil and I. M. Akan (2013). “Atraumatic Flexor tendon retrieval- a simple method.” Ann Surg Innov Res 7(1): 11.

Benefits

Retrieve retracted tendon end with minimal incisions

Reduce the risk of damage to tendon end compared to standard technique*

Potential to avoid repeat suturing of the tendon end

Can be used for both single and dual tendon retrieval

 

* based on cadaver trials

Instructions for Use

To view the Instructions for Use please visit our IFU Library

Order Code

202-1500U FlexPasser™ Tendon Retrieval Kit

View all Reading Room resources

Reading Room

This area may not be suitable for all audiences

Additional Information

For further information, and for details of local distributors and agents, contact our Sales and Marketing team at enquiries@xiros.co.uk

All data listed on this page is held at Xiros and can be requested by contacting enquiries@xiros.co.uk

To request the full range of product documentation or to view any of these documents in a language other than English, please contact us for availability

Always refer to the Instructions for Use which contains detailed information and essential warnings and precautions

Speak to Xiros today about your surgical requirements

Make an enquiry